Mini Cube

(Accelerated Life Testing Lab)

Design

Test room with temperature and humidity control Short and long-term experiments Control room for set-up of parameters, execution of automated programmes and monitoring of the experiment

Internal dimensions 1.30 m x 1.52 m x 2.20 m (L x W x H)
Load Capacity Objects with a mass up to 300 kg

Environment Control

Temperature Range
According to IEC 60068-3-5
-40...+90°C (± 1°C in time ± 2°C in space)
Temperature Rate of Change
According to IEC 60068-3-5

1.7°C/min (-40...+85°C),

1.7°C/min (+85...-0°C),

1°C/min (+0...-40°C)

Relative Humidity +10 °C < T < +90°C
According to IEC 60068-3-6

20...95% (± 5% in time ± 5% in space)

Dew Point Range for Continuous Tests
According to IEC 60068-3-6 

+2…+89°C

Support Services Offered

• Data-acquisition system with ambient T and RH sensors and five 3-wire Pt100-type temperature sensors attachable to the DuT

• Data security management: The system guarantees data integrity and ensures that the data is inaccessible to unauthorised parties

• Support during the whole testing chain: from test design to execution and reporting

 

© Eurac Research